Posts Tagged with Building & Structure

Hydraulic Cylinders Configured as Viscous Damping Devices

Connecting the two sides of the piston in a double-acting, double-rod cylinder through an external adjustable flow control needle valve, transforms the cylinder into a fluid viscous damping device (VDD). Vibrational motion prompts the fluid to transfer from one piston side to the other via the flow control valve, dissipating vibration energy due to the […]

Read More

Gymnasium Floor Vibration Mitigation Using Tuned Mass Dampers

In modern gymnasiums, floor vibrations caused by various activities can be a significant issue, particularly when the gym is situated on higher floors of a multi-story office building. DEICON recently addressed this challenge by supplying two tuned mass dampers (TMDs) to mitigate vibrations in the floor system of one such gym on the 2nd floor […]

Read More



Vibration Control of Long Span Balcony in a Church Using Tuned Mass Dampers

Upon having the construction of a new church near completion, walking induced vibration was perceived on a long span balcony. DEICON conducted on-site measurements and identified the first two natural frequencies of the balcony. In addition, the participating mass and the damping ratio of mode 1 of the balcony were evaluated. DEICON designed and fabricated […]

Read More

Vibration Control of Long Span Balcony in a Church Using Two Tuned Mass Dampers

Upon having the construction of a new church near completion, walking induced vibration was perceived on a long span balcony.  DEICON conducted on-site measurements and identified the first two natural frequencies of the balcony.  In addition, the participating mass and the damping ratio of mode 1 of the balcony was evaluated.  Tuned damping was used […]

Read More


Monumental Staircase Vibration Abatement Using a Tuned Mass Damper-3

To address the vibration of a monumental staircase in an office building, the structural engineer of the project incorporated a 500 lb tuned mass damper (TMD) into the design.  DEICON designed, fabricated the TMD to be installed underneath the landing Figure 1 shows the tuned mass damper. The dynamic attributes of the monumental staircase, namely […]

Read More


Monumental Staircase Vibration Abatement Using a Tuned Mass Damper-2

To lower the vibration level of a monumental staircase, one 500 lb tuned mass damper (TMD) was designed, fabricated, and appended to the structure. The natural frequency of the staircase was measured and used for tuning the TMD. Figure 1 shows the landing of the staircase with two of the measurement locations highlighted. Monumental aesthetically […]

Read More